AC NeverClog Installation Overview

Index

  1. Safety Precautions

  2. ​Evacuation Manifold Installation

  3. Wall Mount Installation

  4. Hooking the Hose Into the System

  5. Hooking the Hose Into the Evacuation Manifold Valve

  6. Connecting the Quick Disconnect Smart Controller

  7. Plugging in the Smart Controller

  8. Smart Life App Configuration

  9. Automation Scheduling

  10. System Testing & Final Steps

  11. ​Technical Specifications

  12. Warranty & Support

Drain line cleaning solution AC NeverClog

1. Safety Precautions

  • Do not plug the controller in yet. 

  • Make sure that your outlet is a 120v GFCI outlet.

Automatic drain line treatment in AC NeverClog system

2. Evacuation Manifold Installation​

  • Locate the exterior drain line for your AC unit.

 

  • Take the provided AC NeverClog ™ evacuation manifold valve (shown above) and install the end of the T onto the drain line of the home. (The condensation will drain out of the clear counterweighted flap valve placed vertically on the drain line. 

 

  • The evacuation manifold valve can also be placed horizontally at a slight downward pitch. It is very important when the valve is placed horizontal that the flap is in the closed position when installed to be most effective as shown.

AC NeverClog evacuation manifold installed on HVAC drain line for clog prevention
AC NeverClog evacuation manifold installed on HVAC drain line for clog prevention
Wall mounting hardware for AC NeverClog drain line system

3. Wall Mount Installation

  • The wall mount has 3 screw holes. All 3 are required for the wall mount to support the AC NeverClog ™ after it has evacuated your ac drain line. Please use the appropriate anchor hardware per the

  • substrate you are mounting into.  (wood screws for wood & tap cons for brick and or concrete). We have installed anchors and screws for ease of installation that should work with any substrate. 

  • Make sure the device is oriented correctly as shown here and that you have placed it so that the AC NeverClog ™ tank will be a minimum of 6” off the ground.

  • After anchoring the mount into the wall, place the AC Neverclog ™ on to the wall mount by the ears sticking out on the left and right side of the exhaust side of the machine.

  • Turn the unit to the on position ( I ) and leave it there permanently.*

Wall mount bracket for installing AC NeverClog HVAC drain line device
AC NeverClog evacuation manifold valve for drain line clearing

4. Hooking the hose into the AC NeverClog

 

  • You are now ready to plug the hose into your AC NeverClog device. Make sure to take the elbow side with black insert and push it into the front of the AC NeverClog as shown.

AC NeverClog automatic HVAC drain line clog prevention system installed
AC drain line connection point for AC NeverClog installation

5. Hooking the hose into the Evacuation Manifold Valve

  • Plug the hose end with the nipple into the T as shown here.

Evacuation manifold valve used to clear and protect AC drain lines
AC NeverClog smart controller easy and mobile drain line maintenance

6. Connecting the Quick Disconnect Smart Controller

  • The quick disconnect has an ip68 waterproof rating and specifically designed to be easily replaceable. Simply line up the two ends, push in and twist the collar to lock it in place 

Waterproof quick connect fittings with locking collars for AC NeverClog drain line system
Powered AC NeverClog controller for continuous drain protection

7. Plugging in the Smart Controller

  • You are now ready to plug your Smart Controller in and let the pre-program run or program the device to your phone using the Smart Life App after creating your own schedule.

  • If you choose the pre-program, you’ve now completed your installation.

Smart AC NeverClog controller for automatic HVAC drain line clog prevention
Smart AC drain line monitoring with AC NeverClog controller

8. Smart Life App Configuration

  1. Download the Smart Life App from the App store 

  2. Register a new account

  3. Log in

  4. Then press and hold the on/off switch on the AC NeverClog smart controller for 6 seconds.

  5. The AC NeverClog logo should pop up on the Smart Life App screen. If it does not, then hit the + button on the top right of the screen. 

  6. The AC NeverClog logo should pop up immediately to be connected. Follow the sequence until it is connected.

  7. Enter the Wi/Fi credentials.

  8. You have now connected the AC NeverClog controller to the Smart Life App and ready for automation scheduling.

AC NeverClog smart controller setup screen during drain line installation
Automated AC drain line maintenance process using AC NeverClog

9. Automation Scheduling

  1. Tap Schedule > Add Schedule

  2. Select Circulate as the timing type.

  3. Set your Start Time to ex: 2:00 PM

  4. Set your End Time to 2:03

  5. Select each day of the week so that all are highlighted in orange.

  6. Open duration: Physically select 1 min

  7. Closed duration: Physically select 1 min 

  8. Then hit Confirm at the bottom right of the page. 

  9. Then click Save at the top right. You are now programmed for daily operation of your new AC NeverClog.

AC NeverClog controller interface used to control automatic drain line cleaning
AC NeverClog system status indicators showing HVAC drain line operation
Protected HVAC drain line with AC NeverClog clog prevention

10. System Testing and Final Steps

  • The suction head button must be pressed forward into the ( l ) position so that it is in the ON position to work correctly. 

  • Manually activate the system by quickly pressing the Smart Controllers on/off button, not the AC NeverClog button.

  • Confirm suction and allow the system to run for at least 1-2 minutes for the first evacuation while fully connected. 

  • After shutting the device off after 1 minute empty the AC NeverClog tank by releasing the 2 tabs on the left and right side of the unit. 

  • Empty it out and repeat until the water coming into the unit is clear. 

  • You now have a clean AC drain line and ready for Automatic daily running of your new AC NeverClog.

Integrated AC drain line clog prevention system components

11. Technical Specifications

  • Feature

  • Value

  • Operating Voltage

  • 120 VAC 60 Hz

  • Suction

  • Every 24 hours

  • Duration

  • 60 Seconds

  • Timer Interval

  • 24 hr programmable

  • Temp Range

  • 32–140°F (0–60°C)

  • Below 60°F unit is designed not to operate

Professional HVAC installation support for AC NeverClog system

12. Warranty & Support

Warranty: 2 years (AC NeverClog ™ device) Covers: Manufacturing defects in workmanship or materials. 2 Year on the automation dongle with waterproof IP68 connection. Shipping to and from at the customers expense.

 

Support Contact:

RESOURCES

COMPANY

LEGAL

Contact

Careers

Business Partnership

Our Mission

Terms Of Use

Web Privacy 

Refund Policy

Terms Of Sale

PRODUCTS

AC NeverClog

Comparison Charts

Installation Accessories

Subscription Options

Where to Buy

Partner Integrations

Replacement Parts

Mobile App

AC NeverClog maintenance components for HVAC condensate drain line protection

FOR BUSINESS

Installer Program

Distributor Program

Partner Portal Login

Marketing Materials Access

  • Instagram
  • Facebook

AC NeverClog’s mission is to automate HVAC condensate drain line management to prevent damage, save time, and bring peace of mind.

@2025 HVAC Technology Solutions

bottom of page